COMPARISON ANALYSIS OF PILE FOUNDATION CAPACITY SINGLE BASED ON PILE LOADING WITH PDA TEST ON SHAKING PORT DEVELOPMENT PROJECTCONTAINERS (APRON SLAB ON PILE) JAYAPURA

Main Article Content

Duha Awaluddin Kurniatullah

Abstract

The foundation is the main structure in a construction which functions as a support for the load or transmits the forces that occur above the construction and is transmitted into the hard soil. Pile foundations are part of the type of deep foundation that is widely used. In designing deep foundations using piles, there are several analytical methods to determine the bearing capacity of deep foundations.The purpose of this study is to calculate and compare the axial bearing capacity of single piles from the Meyerhoff SPT method data, the calendaring data from the Hiley method, ENR, WIKA, Eytelwein Chellis, Navy-Mc, Kay, Gates, Danish, and MSHoC, against the results of the test. PDA test axial bearing capacity. As for the calculation of the lateral bearing capacity using the Broms method.There is a difference in the value of the calculation results of bearing capacity and foundation settlement, both in terms of the calculation method and its location. Based on the calculation results of single pile axial bearing capacity with SPT data = 285,520 tons, calendaring data, Hiley = 336,994 tons, ENR = 50,156 tons, WIKA = 336,994 tons, Eytelwein Chellis = 88,718 tons, Navy-Mc, Kay = 5302,720 tons, Gates = 2802.460 tons, Danish = 9968.484 tons, MSHoC = 62.695 tons, while the results of the single pile axial bearing capacity using the PDA test obtained the results of = 392,000 tons. As for the calculation of the lateral bearing capacity of a single pile using the Broms method for the criteria for the pinned end pile foundation to be considered a long pile or not rigid, and the results obtained that the ultimate lateral force that can be resisted by the long wedged end pile is = 114.463 kg, and for The lateral allowable that can be resisted by the long pinned pile is = 38,154 kg, while the amount of deflection that occurs due to the allowable lateral force on the long wedged end pile foundation is 0.00549 mm. Differences in axial bearing capacity can be caused by differences in soil types, the way the test is carried out which depends on the accuracy of the operator and differences in the parameters used in the calculations.

Article Details

How to Cite
[1]
D. Kurniatullah, “COMPARISON ANALYSIS OF PILE FOUNDATION CAPACITY SINGLE BASED ON PILE LOADING WITH PDA TEST ON SHAKING PORT DEVELOPMENT PROJECTCONTAINERS (APRON SLAB ON PILE) JAYAPURA”, JURNAL EDUCATION AND DEVELOPMENT, vol. 9, no. 4, pp. 737-743, Nov. 2021.
Section
Artikel

References

Bowles, J., E., 1991,Analisa dan Desain Pondasi, EdisiKeempatJilid 1, Erlangga, Jakarta.
Bowles, J., E.,1991,Analisa dan Desain Pondasi,Edisi Keempat Jilid 2, Erlangga,Jakarta.
Das,Braja M., 2007,Principle of Foundation Engineering, Christopher M.Shortt, Global Engineer.
Habibah, Lim, 2015, Analisis Daya Dukung Pondasi TiangPancang Tunggal Akibat Gaya Lateral, Jurnal Teknik Sipil Universitas Pakuan : 1-8.
Hardiyatmo, HaryChristiady, 1996,Teknik Pondasi 1, PT Gramedia Pustaka Utama, Jakarta.
Hardiyatmo,HaryChristiady, 2002,Teknik Pondasi 2, PT Gramedia Pustaka Utama, Jakarta.
Hardiyatmo, HaryChristiady, 2011,Analisis dan PerancanganPondasi II, Gajah Mada University Press, Yogyakarta.
Hardiyatmo,HaryChristiady, 2014, Analisis dan PerancanganFondasi I, Gajah Mada University Press, Yogyakarta.
Hidayat,Wahyu, 2008,Tugas Akhir, Analisis Daya Dukung Pondasi TiangPancangPadaProyek Pembangunan Islamic Center Kabupaten Kampar-Riau, Departemen Teknik Sipil, Universitas SumateraUtara, Medan.
HS. Sardjono, 1987,PondasiTiangPancangJilid I, Sinar Wijaya, Surabaya.
Legrans,Roski R. I. ImbarSesty, 2011,TinjauanDayaDukungPondasiTiangPancang Pada Tanah BerlapisBerdasarkan Hasil Uji PenetrasiStandar (SPT) (StudiKasus Lokasi Pembangunan Jembatan Lahar Naha), TeknoSipil Vol. 9.
Mahadhir, Muhammad, Tanjung, 2018,Tugas Akhir, Analisis Daya Dukung Pondasi TiangPancang Tuggal Diameter 0,6 meter Dengan Metode Analitis dan MetodeElemenHingga Pada Proyek Overpass DesaManunggal Jalan Akses Tol Medan-Binjai, Departemen Teknik Sipil, Universitas SumateraUtara, Medan.
Muhammad, Adnan, Ismail, 2014,Tugas Akhir, Analisa Daya DukungTiang Statis Dan DinamisPadaPembangunan Pelabuhan Batu Bara PT. Semen TonasaKabupatenPangkep– Sulawesi Selatan, Departemen TeknikSipil, Universitas Hasanuddin, Makassar.
Nakazawa, Kazuto, 2000,Mekanika Tanah dan Teknik Pondasiditerjemah oleh Ir. L. Lauludkk, Pradnya Paramita, Jakarta.
Raharjo,P., P.,2005,Manual Pondasi Tiang, Edisi ketiga,GEC- Geotechnical Engineering Centre, Bandung.
Ralph Peck B.,dkk, 1996,Teknik Fondasi,Gadjah Mada University Press, Yogyakarta.
Suyono, Sosrodarsono, 2005,Mekanika Tanah dan Teknik Pondasi, PT Pradnya Paramita, Jakarta.
Tindoan,Tua, 2014, AnalisisDayaDukung dan PancangBetonJembatan Sungai Penara Jalan Akses Non Tol Kualanamu, Jurnal Teknik Sipil 2014.